Receptacles, switches & lighting
New outlets where you need them, switch replacements, lighting installs, and ceiling fans — down to a single receptacle.
Fortner Electric LLC is a licensed, insured electrical contractor — your local electrician for homes and small businesses across Elgin, Columbia, Lexington and Irmo, SC. No job is too small, and every job is done to National Electrical Code standards.
Residential and light commercial electrical work across the Midlands. A few of the jobs we handle every week — the full list is on the Services page.
New outlets where you need them, switch replacements, lighting installs, and ceiling fans — down to a single receptacle.
Full and partial rewires for older homes, plus new circuits and panel work to bring a house up to current code.
Whole-house surge protectors, smoke detector replacement and troubleshooting, and electrical safety fixes.
Dedicated circuits for EV chargers and appliances, wired and breaker-matched for the load.
Receptacles and dedicated equipment circuits for shops and restaurants — including after-hours scheduling so your doors stay open.
Dead outlets, tripping breakers, flickering lights — we find the fault and fix it to code, not around it.
Searching for an electrician near you? Fortner Electric is based in Elgin, SC and takes residential and light commercial jobs across the Columbia metro and the Midlands:
…and surrounding Midlands communities. Wherever the job is in the area, you get the same deal: a licensed, insured master electrician, flat-rate pricing, and work done to code. Call (803) 900-3666.
Five-star Google review for a job in Lexington, SC — new outlets installed and a whole-house surge protector fitted.
Residential and light commercial electrical work, done to National Electrical Code (NEC) standards. Jobs run from installing a single receptacle to complete home rewiring — the size of the job doesn't change the standard of the work. If you're looking for a local electrician in the Columbia, Elgin, Lexington or Irmo area, this is the full list of what we take on.
Flat rate pricing — message for a quote. Onsite consultations available.
In the Elgin / Columbia area, inspections don't need a scheduled appointment — Troy calls the inspector when the job is about done. When there's an inspection wait, you choose: Troy waits on site (billable time), or you wait and provide jobsite access at no charge.
What customers around Columbia and Elgin ask before they book an electrician.
Fortner Electric uses flat-rate pricing — you get a price for the job, not an open-ended hourly bill. Message or call (803) 900-3666 for a quote; onsite consultations are available.
Yes. Fortner Electric LLC is licensed and insured, and owner Troy Fortner is a Master Electrician who obtained his master license in 2009. All work is performed to National Electrical Code (NEC) standards.
Fortner Electric is based in Elgin, SC and serves Columbia, Lexington, Irmo and surrounding communities across the South Carolina Midlands.
Yes — no job is too small. A single receptacle, a switch replacement or one dead outlet gets the same code-correct standard of work as a complete home rewire.
Yes. Dedicated, breaker-matched circuits for EV chargers and appliances, and whole-house surge protection — along with panel work, lighting, ceiling fans and smoke detectors.
Describe it and get a straight answer — no obligation.
Owner and Master Electrician of Fortner Electric LLC — and a Technical Sergeant in the South Carolina Air National Guard.
Troy is a Master Electrician — he obtained his master license in 2009 — who does residential and light commercial work to National Electrical Code standards — from installing a single receptacle to complete home rewiring. Fortner Electric is licensed and insured, and Troy takes the small jobs as seriously as the big ones: a dead outlet gets the same code-correct fix as a full panel job.
Alongside the business, Troy serves in the South Carolina Air National Guard as a Technical Sergeant (TSgt) in Aircraft Metals Technology (2023–present), drilling one weekend a month — precision metalwork on aircraft components, where tolerances are measured in thousandths and there's no room for "close enough." Before joining the Guard, he served in the Air Force Reserves from 2008 to 2023. That same standard carries straight into his electrical work.
Fortner Electric has completed over 200 work orders across the Midlands — panel upgrades, EV chargers, rewires, and the small repairs other companies won't roll a truck for.
| Trade | Master Electrician — master license obtained in 2009; Fortner Electric LLC, licensed & insured |
|---|---|
| Standard | All work performed to National Electrical Code (NEC) standards |
| Military | Technical Sergeant (TSgt), South Carolina Air National Guard — Aircraft Metals Technology, 2023–present; Air Force Reserves, 2008–2023 |
| Specialty | Aircraft Metals Technology |
| Service area | Elgin, Columbia, Lexington, Irmo & surrounding Midlands communities |
As an Aircraft Metals Technology specialist in the South Carolina Air National Guard, Troy's work is precision fabrication and repair for aircraft:
Photos of Fortner Electric jobs around the Midlands.
Straight answers to the questions Columbia and Elgin homeowners ask us most — costs, tripping breakers, panels, permits, generators, and EV chargers.
Most residential electricians run $75–$150 an hour nationally, plus a service call fee to come out. At Fortner Electric, our rate is $165 an hour, and most jobs are quoted flat before we start — so you know the number before the work begins, not after. Small repairs are usually one visit. Bigger work (panels, EV chargers, new circuits) gets a digital quote first through our CRM, FieldPulse.
A 200-amp panel replacement with us runs $3,800–$4,700. A full service upgrade from 100 to 200 amps runs more because the meter base and service conductors usually change too. What moves the price: panel size, whether the service entrance needs replacing, permit and inspection fees, and how much rework the existing wiring needs. We do a load calculation first so the recommendation is based on numbers, not a guess.
With us, a Level 2 charger install runs $800–$2,000. The big variables are distance from the panel to the charger, whether your panel has spare capacity and breaker space, and whether a panel upgrade has to happen first. The charger itself is separate. We check panel capacity before quoting — a charger on an overloaded panel is a problem waiting to happen.
Our service call (truck roll) is $214.50. Nationally, expect $75–$200 to get an electrician to your door, often with a one-hour minimum for troubleshooting. At Fortner Electric we quote flat before work starts whenever the job allows it.
A breaker trips to protect the wire from overheating — it's doing its job. The usual causes: too much load on one circuit (space heater plus a hair dryer on the same run), a short in a cord or appliance, a ground fault on an outdoor or wet-location circuit, or a breaker that's simply worn out. GFCI and AFCI breakers add two more trip reasons: current leaking to ground, and the sparking signature of a damaged wire. If a breaker trips the instant you reset it, even with everything unplugged, stop resetting it and call us — that points to a short, not an overload.
A GFCI trips when it senses current leaking out of the circuit — exactly what it's built to catch near water. Common causes: rain or condensation inside an outdoor outlet, a damaged extension cord, a pool pump or appliance with a fault, or a GFCI that's worn out. Quick check: unplug everything on the circuit and reset it. If it holds, plug things back in one at a time until it trips — that's your culprit. If it trips with nothing plugged in, the device or the wiring needs attention. Call us.
Check your GFCIs first. One GFCI in a bathroom, kitchen, garage, or outside often protects several plain outlets downstream — when it trips, every outlet after it goes dead, sometimes in another room. Press the reset buttons on every GFCI you can find. If they're all set and the outlet is still dead, the likely cause is a loose or burned connection in one of the outlets on that run. Leave it alone and have an electrician open it up — loose connections get hot.
A tiny dip when a big motor starts can be normal. Flickering across the whole house, or lights dimming hard every time the AC kicks on, points to a loose connection at the panel, the meter, or the service wires — and loose connections heat up. One flickering fixture is usually the bulb, socket, switch, or an LED on an old dimmer. Another common cause of flickering is lights and outlets wired on the same 14 AWG circuit. That's not a code violation, but some homes are built as cost-efficiently as possible, so every time you plug in the vacuum, the lights flicker. Ask your electrician — or contact us — about separating the lights from the outlets. If your AC/HVAC is causing the flickering, ask us about an AC soft start kit; it may be the solution. The pattern to take seriously: lights getting brighter in some rooms while they dim in others. That can mean a failing neutral on the service. Turn off sensitive electronics and call your utility and a licensed electrician.
Stop using it. Heat, discoloration, or a burning/fishy smell at an outlet or switch means a loose connection or failing device — that's a fire risk, not a nuisance. Same goes for a warm panel door, buzzing or crackling from the panel, or scorch marks. Turn off the breaker to that circuit if you can identify it, and call an electrician.
Yes — this one's not hype. Federal Pacific Stab-Lok breakers have a documented record of failing to trip under overload; testing found failure rates of 25% or more, and higher after repeated surges. A breaker that doesn't trip defeats the whole purpose of the panel. Zinsco carries the same concern. The Consumer Product Safety Commission flagged Federal Pacific panels as a latent safety hazard decades ago, and many insurance companies now surcharge, require replacement, or decline homes that still have them. If your home was built between the 1950s and the 1980s, check the brand on your panel door. If it says Federal Pacific, FPE, Stab-Lok, or Zinsco, plan on replacing it. "It's been fine so far" means untested, not safe — a breaker's job only exists during a fault.
Signs: breakers trip often or won't stay reset, lights flicker across the house, you smell burning or see scorch marks at the panel, the panel is rusted or has water in it, you're still on a fuse box or 60–100 amp service, or there's no spare space left and you're adding an EV charger, hot tub, or addition. A licensed electrician can open the panel (home inspectors usually don't), check the bus and terminations for heat damage, and give you a straight answer: fine, watch, or replace — with a real price for each.
Replace the batteries every year, and replace the whole detector every 10 years — the sensor wears out even if it still chirps on test. Hardwired detectors should be interconnected so when one goes off, they all do, and each one needs battery backup for outages. Newer 10-year sealed-battery units skip the yearly battery swap. If yours are past 10 years old, they're due.
For most homes, yes. A surge protector at the panel protects everything downstream — HVAC boards, appliances, TVs, computers — from utility surges and lightning-induced spikes that plug-in strips can't stop. The NEC now requires surge protection on new dwelling services, which tells you where the code is headed. It's a one-time install at the panel, and it's cheap insurance compared to replacing a control board.
For most work beyond a like-for-like swap, yes. Panel upgrades, service changes, new circuits, EV charger wiring, generator connections, and hot tub or pool wiring all need a permit and inspection in our area. Replacing a worn-out outlet or light fixture in the same spot usually doesn't. Unpermitted work can void insurance coverage on a fire claim and complicate a home sale. We pull the permit and schedule the inspection as part of the job — you don't chase paperwork. One more thing about local AHJs (Authorities Having Jurisdiction): a project like a panel upgrade will trigger other code updates in most jurisdictions. These can include installing interconnected smoke/CO detectors, adding AFCI/GFCI protection, installing a new grounding electrode conductor assembly, and more. It's always recommended to reach out to the local inspector and ask.
Not into a wall outlet — ever. Backfeeding power through an outlet can energize the utility lines and kill a lineman working to restore your service, and it destroys your generator when utility power comes back. The legal, safe ways: a manual transfer switch, a generator interlock kit with an inlet box, or an automatic transfer switch for a standby unit. All three physically prevent your generator and the utility from being connected at the same time, which is what NEC Article 702 requires. We install inlet boxes and interlock kits for portable generators — that's the most cost-effective legal setup for most homes.
Both do the same job — keep your generator and the power company separated. A transfer switch is a separate panel where you flip selected circuits over by hand. An interlock kit is a sliding plate on your main panel that makes it physically impossible for the main breaker and the generator breaker to be on at the same time. The interlock is usually cheaper and lets you choose which circuits to power on the fly, as long as you manage the load. Either way, it needs a licensed electrician and a permit.
Not always. It depends on your panel's capacity and spare breaker space, which is why we run a load calculation before quoting. A 200-amp panel with room to spare usually takes a charger fine. A full 100-amp panel with an electric range, dryer, and AC may need an upgrade first — or a load-management device that pauses charging when the house is drawing heavy. We check the numbers and tell you straight.
With us, adding an outlet or a new circuit runs $389–$746.50 depending on access and distance. The price drivers are how far the run is, whether the walls are open or finished, and attic or crawl-space access. We quote flat before starting.
Yes — customer-supplied fixtures are common, and installs on existing wiring run $168–$448 with us. The one thing we check first is the box: a ceiling fan needs a fan-rated box braced to structure, not a standard light box. If the existing box isn't rated for it, we swap it as part of the install.
Yes. Hot tubs need a dedicated GFCI-protected circuit sized to the tub's nameplate, a disconnect within sight, and bonding — all inspected. It's not a plug-it-in appliance, and the combination of water and high current is exactly where code exists for a reason.
Call, email, or send the form — it opens your email app with everything filled in, ready to send to Fortner Electric.
One receptacle or a whole rewire — call Fortner Electric.